Simultaneous multi‐slice cardiac cine with Fourier‐encoded self‐calibration at 7 Tesla

Archive ouverte

Rapacchi, Stanislas | Troalen, Thomas | Bentatou, Zakarya | Quemeneur, Morgane | Guye, Maxime | Bernard, Monique | Jacquier, Alexis | Kober, Frank

Edité par CCSD ; Wiley -

International audience. PurposeTo accelerate cardiac cine at 7 tesla using simultaneous multi‐slice (SMS) acquisition with self‐calibration to resolve misalignment between calibration and imaging data due to breathing motion.MethodsA spoiled‐gradient echo cine sequence was modified with radiofrequency phase‐cycled SMS excitations. A Fourier encoding strategy was applied along the cardiac phase dimension to allow for slice untangling and split‐slice GRAPPA calibration. Split‐slice GRAPPA was coupled with regular GRAPPA (SMS‐GRAPPA) and L1‐SPIRiT (SMS‐L1SPIRiT) for image reconstruction. 3‐slice SMS cine MRI was evaluated in ten subjects against single‐slice cine MRI in terms of SNR and contrast‐to‐noise ratio and slice leakage.ResultsSNR decreased significantly from 10.1 ± 7.1 for single‐slice cine to 7.4 ± 2.8 for SMS‐GRAPPA (P = 0.02) and was recovered to 9.0 ± 4.5 with SMS‐L1SPIRiT (P = 0.02). Contrast to noise ratio decreased significantly from 14.5 ± 8.1 for single‐slice cine to 5.6 ± 3.6 for SMS‐GRAPPA (P < 0.0001) and increased slightly but significantly back to 6.7 ± 4.4 for SMS‐L1SPIRiT (P = 0.03). Specific absorption rate restrictions imposed a reduced nominal flip angle (−37 ± 7%, P = 0.02) for 3‐slice SMS excitations compared to single‐slice acquisitions. SMS slice leakage increased significantly from apex (8.6 ± 6.5 %) to base (13.1 ± 4.1 %, P = 0.03) in the left ventricle.ConclusionThree‐fold acceleration of cine at 7T was achieved using the proposed SMS technique. Fourier encoding self‐calibration and regularized image reconstruction enabled simultaneous acquisition of three slices without significant SNR decrease but significant CNR decrease linked to the reduced nominal excitation flip angle.

Suggestions

Du même auteur

Prognostic value of cardiovascular magnetic resonance T1 mapping and extracellular volume fraction in nonischemic dilated cardiomyopathy

Archive ouverte | Cadour, Farah | CCSD

International audience. Abstract Background Heart failure- (HF) and arrhythmia-related complications are the main causes of morbidity and mortality in patients with nonischemic dilated cardiomyopathy (NIDCM). Cardio...

Tuning Blipped CAIPIRINHA for simultaneous multi-slice (SMS) balanced SSFP cardiac imaging

Archive ouverte | Bentatou, Zakarya | CCSD

International audience

Tuning Blipped CAIPIRINHA for simultaneous multi-slice single-shot balanced SSFP imaging

Archive ouverte | Bentatou, Zakarya | CCSD

International audience

Chargement des enrichissements...