Value of ultra-low-dose chest CT with iterative reconstruction for selected emergency room patients with acute dyspnea

Archive ouverte

Macri, Francesco | Greffier, Joël | Pereira, F. | Rosa, Alina Chica | Khasanova, Elina | Claret, Pierre-Geraut | Larbi, Ahmed | Gualdi, Gianfranco | Beregi, Jean Paul

Edité par CCSD ; Elsevier -

International audience. OBJECTIVE:To compare the diagnostic confidence between low-dose computed-tomography (LDCT) and ultra-low-dose CT (ULDCT) of the chest on a single source CT system (SSCT) for patients with acute dyspnoea.MATERIALS AND METHODS:One hundred thirty-three consecutive dyspnoeic patients referred from the emergency room (ER) were selected to undergo two sequential non-enhanced chest CT acquisitions: LDCT first acquisition (100kVp and 60mAs), followed by ULDCT (100kVp±20 and 10mAs). Images were reconstructed with sinogram affirmed reconstruction (SAFIRE). Objective and subjective image quality assessments were made. Two radiologists evaluated subjective image quality and the level of diagnostic confidence as certain or uncertain.RESULTS:The mean effective doses (ED) were 1.164±0.403 and 0.182±0.028mSv for LDCT and ULDCT, respectively. Objective image quality improved significantly on lung images of ULDCT compared with LDCT (p<0.05). Subjective image quality was rated excellent/good in 90% of patients with BMI=25kg/m(2) for ULDCT. The level of diagnostic confidence was "certain" in all cases for both radiologists with excellent inter-observer agreement (k=1).CONCLUSION:Chest ULDCT with SAFIRE on a SSCT allows a high level diagnostic confidence for the evaluation of selected acute dyspnoeic patients.

Consulter en ligne

Suggestions

Du même auteur

Minor Blunt Thoracic Trauma in the Emergency Department: Sensitivity and Specificity of Chest Ultralow-Dose Computed Tomography Compared With Conventional Radiography

Archive ouverte | Macri, Francesco | CCSD

International audience. Study objective:To evaluate the diagnostic performance of chest ultralow-dose computed tomography (CT) compared with chestradiograph for minor blunt thoracic trauma.Methods:One hundred sixty ...

Interventional spine procedures under CT guidance: How to reduce patient radiation dose without compromising the successful outcome of the procedure?

Archive ouverte | Greffier, Joël | CCSD

International audience. This technical note proposes a method to reduce radiation dose for spine interventions under CT guidance without compromising the successful outcome of the procedure. Two consecutive periods ...

EFFECT OF PATIENT SIZE, ANATOMICAL LOCATION AND MODULATION STRENGTH ON DOSE DELIVERED AND IMAGE-QUALITY ON CT EXAMINATION

Archive ouverte | Greffier, Joël | CCSD

International audience. To study the effect of patient size, anatomical location and modulation strength (MS) on image-quality and delivered dose of CT scans acquired with automatic-exposure-control system (AEC). Fo...

Chargement des enrichissements...