Assessment of Bowel Wall Enhancement for the Diagnosis of Intestinal Ischemia in Patients with Small Bowel Obstruction: Value of Adding Unenhanced CT to Contrast-enhanced CT

Archive ouverte

Chuong, Anh Minh | Corno, Lucie | Beaussier, Hélène | Boulay-Coletta, Isabelle | Millet, Ingrid | Hodel, Jérôme | Taourel, Patrice | Chatellier, Gilles | Zins, Marc

Edité par CCSD ; Radiological Society of North America -

International audience. Purpose To determine whether adding unenhanced computed tomography (CT) to contrast material-enhanced CT improves the diagnostic performance of decreased bowel wall enhancement as a sign of ischemia complicating mechanical small bowel obstruction (SBO). Materials and Methods This retrospective study was approved by the institutional review board, which waived the requirement for informed consent. Two gastrointestinal radiologists independently performed retrospective assessments of 164 unenhanced and contrast-enhanced CT studies from 158 consecutive patients (mean age, 71.2 years) with mechanical SBO. The reference standard was the intraoperative and/or histologic diagnosis (in 80 cases) or results from clinical follow-up in patients who did not undergo surgery (84 cases). Decreased bowel wall enhancement was evaluated with contrast-enhanced images then and both unenhanced and contrast-enhanced images 1 month later. Diagnostic performance of decreased bowel wall enhancement and confidence in the diagnosis were compared between the two readings by using McNemar and Wilcoxon signed rank tests. Interobserver agreement was assessed by using κ statistics and compared with bootstrapping. Results Ischemia was diagnosed in 41 of 164 (25%) episodes of SBO. For both observers, adding unenhanced images improved decreased bowel wall enhancement sensitivity (observer 1: 46.3% [19 of 41] vs 65.8% [27 of 41], P = .02; observer 2: 56.1% [23 of 41] vs 63.4% [26 of 41], P = .45), Youden index (from 0.41 to 0.58 for observer 1 and from 0.42 to 0.61 for observer 2), and confidence score (P < .001 for both). Specificity significantly increased for observer 2 (84.5% [104 of 123] vs 94.3% [116 of 123], P = .002), and interobserver agreement significantly increased, from moderate (κ = 0.48) to excellent (κ = 0.89; P < .0001). Conclusion Adding unenhanced CT to contrast-enhanced CT improved the sensitivity, diagnostic confidence, and interobserver agreement of the diagnosis of ischemia, a complication of mechanical SBO, on the basis of decreased bowel wall enhancement. (©) RSNA, 2016.

Consulter en ligne

Suggestions

Du même auteur

CT diagnosis of closed loop bowel obstruction mechanism is not sufficient to indicate emergent surgery

Archive ouverte | Rondenet, Camille | CCSD

International audience. To identify computed tomography (CT) findings associated with successful conservative treatment of closed loop small bowel obstruction (CL-SBO) due to adhesions or internal herniation. Materi...

Increased unenhanced bowel-wall attenuation: a specific sign of bowel necrosis in closed-loop small-bowel obstruction

Archive ouverte | Rondenet, Camille | CCSD

International audience. OBJECTIVES: To identify computed tomography (CT) findings associated with bowel necrosis in patients with surgically confirmed strangulating closed-loop small-bowel obstruction (CL-SBO) due t...

Acute Jejunoileal Diverticulitis: Multicenter Descriptive Study of 33 Patients

Archive ouverte | Lebert, Paul | CCSD

International audience. OBJECTIVE: Acute jejunoileal diverticulitis is a very rare and potentially serious disease affecting mostly elderly patients. The diagnosis is based on imaging but remains underrecognized. Th...

Chargement des enrichissements...