Embolization with ethylene vinyl alcohol copolymer (Onyx®) for peripheral hemostatic and non-hemostatic applications: a feasibility and safety study

Archive ouverte

Né, Romaric | Chevallier, Olivier | Falvo, Nicolas | Facy, Olivier | Berthod, Pierre-Emmanuel | Galland, Christophe | Gehin, Sophie | Midulla, Marco | Loffroy, Romaric

Edité par CCSD ; AME Publishing -

International audience. Background: Onyx® is a liquid embolic agent, which is approved for the treatment of cerebral vascular lesions but still rarely used in peripheral interventional radiology. The goal of this study is to report the feasibility and safety of embolization with Onyx® for peripheral hemostatic and non-hemostatic endovascular procedures.Methods: Retrospective study of all consecutive patients who underwent visceral or peripheral embolization with Onyx® for hemostatic or non-hemostatic purpose in our department between May 2014 and November 2016. Demographic data, clinical presentation, underlying etiology, culprit vessel, endovascular procedure, pain during embolization, outcomes, and follow-up data were collected.Results: Fifty patients (males, 34; females, 16; mean age, 56±18 years; range, 15–89 years) were included. Twenty-nine (58%) of patients underwent hemostatic embolization for arterial (n=22, 44%) or venous (n=7, 14%) bleeding lesions, whereas 21 (42%) of patients underwent non-hemostatic embolization for arterial aneurysms (n=8, 16%), preoperative portal vein deprivation (n=6, 12%) or other indications (n=7, 14%). Onyx-18 was used in 37 (74%) patients, Onyx-34 in 9 (18%) patients, and a combination of both in 4 (8%) patients. Onyx was used alone in 25 (50%) patients and in combination with other agent in 25 (50%) patients. Mean number of Onyx® vials used was 3.7 (range, 1–17). Immediate technical success rate was 100%. Primary clinical success was achieved in all patients. Recurrent bleeding occurred in two patients. Significant pain (pain score ≥3) was noted during injection in 10 (20%) patients. No major complication or side effects were noted within 1 month.Conclusions: Transcatheter embolization with Onyx® is feasible and safe in the peripheral arterial or venous vasculature for both bleeding and non-bleeding patients whatever the anatomic site.

Consulter en ligne

Suggestions

Du même auteur

Endovascular management of arterial injuries after blunt or iatrogenic renal trauma

Archive ouverte | Loffroy, Romaric | CCSD

International audience. The kidney is the third most common abdominal organ to be injured in trauma, following the spleen and liver, respectively. The most commonly used classification scheme is the American Associa...

Combined HawkOne directional atherectomy and paclitaxel-coated balloon angioplasty for isolated calcified popliteal artery lesion: a no-stent approach to lower extremity endovascular revascularization

Archive ouverte | Loffroy, Romaric | CCSD

International audience. Restenosis rate after percutaneous transluminal angioplasty (PTA) of isolated calcified popliteal artery lesion makes this endovascular procedure still debated. Indeed, the presence of severe...

Outcomes of Transcatheter Arterial Embolization with a Modified N-Butyl Cyanoacrylate Glue for Spontaneous Iliopsoas and Rectus Sheath Hematomas in Anticoagulated Patients

Archive ouverte | Jawhari, Rany | CCSD

International audience. PurposeTo assess the efficacy and safety of n-butyl cyanoacrylate methacryloxy sulfolane (NBCA-MS) transcatheter arterial embolization for anticoagulation-related soft-tissue bleeding and to ...

Chargement des enrichissements...