Track structure modeling in liquid water: A review of the Geant4-DNA very low energy extension of the Geant4 Monte Carlo simulation toolkit

Archive ouverte

Bernal, M. A. | Bordage, M.-C. | Brown, J.M.C. | Davídková, Marie | Delage, E. | El Bitar, Z. | Enger, S. | Francis, Z. | Guatelli, S. | Ivanchenko, V. N. | Karamitros, M. | Kyriakou, I. | Maigne, L. | Meylan, S. | Murakami, K. | Okada, S. | Payno, H. | Petrovic, I. | Pham, Q.T. | Ristic-Fira, A. | Sasaki, T. | Stepan, V. | Tran, H. N. | Villagrasa, C. | Incerti, S.

Edité par CCSD ; Elsevier -

International audience. Understanding the fundamental mechanisms involved in the induction of biological damage by ionizing radiation remains a major challenge of today's radiobiology research. The Monte Carlo simulation of physical, physicochemical and chemical processes involved may provide a powerful tool for the simulation of early damage induction. The Geant4-DNA extension of the general purpose Monte Carlo Geant4 simulation toolkit aims to provide the scientific community with an open source access platform for the mechanistic simulation of such early damage. This paper presents the most recent review of the Geant4-DNA extension, as available to Geant4 users since June 2015 (release 10.2 Beta). In particular, the review includes the description of new physical models for the description of electron elastic and inelastic interactions in liquid water, as well as new examples dedicated to the simulation of physicochemical and chemical stages of water radiolysis. Several implementations of geometrical models of biological targets are presented as well, and the list of Geant4-DNA examples is described.

Consulter en ligne

Suggestions

Du même auteur

Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes

Archive ouverte | André, T. | CCSD

Monte Carlo simulations of S-values have been carried out with the Geant4-DNA extension of the Geant4 toolkit. The S-values have been simulated for monoenergetic electrons with energies ranging from 0.1 keV up to 20 keV, in liquid...

Risk of eye lens radiation exposure for members of the public

Archive ouverte | Chevallier, M.-A. | CCSD

International audience. In 2011, the International Commission on Radiological Protection (ICRP) reviewed its recommendation concerning the equivalent dose limit for the eye lens, lowering it to 20 mSv in a year, for...

Cancer sentinelle Project: a regional network to enable cancer data exchange in Auvergne

Archive ouverte | de Vlieger, Paul | CCSD

PCSV. International audience

Chargement des enrichissements...