Variations in trihalomethane levels in three French water distribution systems and the development of a predictive model.

Archive ouverte

Mouly, Damien | Joulin, Eric | Rosin, Christophe | Beaudeau, Pascal | Zeghnoun, Abdelkrim | Olszewski-Ortar, Agnès | Munoz, Jean François | Welté, Bénédicte | Joyeux, Michel | Seux, René | Montiel, Antoine | Rodriguez, M J

Edité par CCSD ; IWA Publishing/Elsevier -

International audience. Epidemiological studies have demonstrated that chlorination by-products in drinking water may cause some types of cancer in humans. However, due to differences in methodology between the various studies, it is not possible to establish a dose-response relationship. This shortcoming is due primarily to uncertainties about how exposure is measured-made difficult by the great number of compounds present-the exposure routes involved and the variation in concentrations in water distribution systems. This is especially true for trihalomethanes for which concentrations can double between the water treatment plant and the consumer tap. The aim of this study is to describe the behaviour of trihalomethanes in three French water distribution systems and develop a mathematical model to predict concentrations in the water distribution system using data collected from treated water at the plant (i.e. the entrance of the distribution system). In 2006 and 2007, samples were taken successively from treated water at the plant and at several points in the water distribution system in three French cities. In addition to the concentrations of the four trihalomethanes (chloroform, dichlorobromomethane, chlorodibromomethane, bromoform), many other parameters involved in their formation that affect their concentration were also measured. The average trihalomethane concentration in the three water distribution systems ranged from 21.6 μg/L to 59.9 μg/L. The increase in trihalomethanes between the treated water at the plant and a given point in the water distribution system varied by a factor of 1.1-5.7 over all of the samples. A log-log linear regression model was constructed to predict THM concentrations in the water distribution system. The five variables used were trihalomethane concentration and free residual chlorine for treated water at the plant, two variables that characterize the reactivity of organic matter (specific UV absorbance (SUVA), an indicator developed for the free chlorine consumption in the treatment plant before distribution δ) and water residence time in the distribution system. French regulations impose a minimum trihalomethane level for drinking water and most tests are performed on treated water at the plant. Applied in this context, the model developed here helps better to understand trihalomethane exposure in the French population, particularly useful for epidemiological studies.

Consulter en ligne

Suggestions

Du même auteur

Évaluation des risques sanitaires liés aux situations de contamination physico-chimique des eaux de boisson : le cas des ions perchlorate et bromate

Archive ouverte | Cartier, Thomas | CCSD

International audience. L'Agence nationale de sécurité sanitaire de l'alimentation, de l'environnement et du travail (Anses) évalue notamment les risques sanitaires liés aux situations de dépassement des limites et ...

Avis de l'Anses relatif à un projet de décret et quatre projets d’arrêtés transposant les dispositions de la directive (UE) 2020/2184 relative à la qualité des eaux destinées à la consommation humaine (Lot 3)

Archive ouverte | Bornert, Gilles | CCSD

Citation suggérée : Anses. (2022). Avis relatif à un projet de décret et quatre projets d’arrêtés transposant les dispositions de la directive (UE) 2020/2184 relative à la qualité des eaux destinées à la consommation humaine (Lot ...

Avis de l'Anses relatif à trois projets d’arrêtés et un avis associé transposant les dispositions de la directive (UE) 2020/2184 relative à la qualité des eaux destinées à la consommation humaine (Lot 1)

Archive ouverte | Bornert, Gilles | CCSD

Citation suggérée : Anses. (2022). Avis relatif à trois projets d’arrêtés et un avis associé transposant les dispositions de la directive (UE) 2020/2184 relative à la qualité des eaux destinées à la consommation humaine (Lot 1) (s...