Early prediction of pathological response in locally advanced rectal cancer based on sequential (18)F-FDG PET.

Archive ouverte

Hatt, Mathieu | van Stiphout, Ruud | Le Pogam, Adrien | Lammering, Guido | Visvikis, Dimitris | Lambin, Philippe

Edité par CCSD ; Taylor & Francis -

International audience. Background. The objectives of this study were to investigate the predictive value of sequential (18)F-FDG PET scans for pathological tumor response grade (TRG) after preoperative chemoradiotherapy (PCRT) in locally advanced rectal cancer (LARC) and the impact of partial volume effects correction (PVC). Methods. Twenty-eight LARC patients were included. Responders and non-responders status were determined in histopathology. PET indices [SUV max and mean, volume and total lesion glycolysis (TLG)] at baseline and their evolution after one and two weeks of PCRT were extracted by delineation of the PET images, with or without PVC. Their predictive value was investigated using Mann-Whitney-U tests and ROC analysis. Results. Within baseline parameters, only SUV(mean) was correlated with response. No evolution after one week was predictive of the response, whereas after two weeks all the parameters except volume were, the best prediction being obtained with TLG (AUC 0.79, sensitivity 63%, specificity 92%). PVC had no significant impact on these results. Conclusion. Several PET indices at baseline and their evolution after two weeks of PCRT are good predictors of response in LARC, with or without PVC, whereas results after one week are suboptimal. Best predictor was TLG reduction after two weeks, although baseline SUV(mean) had smaller but similar predictive power.

Suggestions

Du même auteur

Denoising of PET images by combining wavelets and curvelets for improved preservation of resolution and quantitation.

Archive ouverte | Le Pogam, Adrien | CCSD

International audience. Denoising of Positron Emission Tomography (PET) images is a challenging task due to the inherent low signal-to-noise ratio (SNR) of the acquired data. A pre-processing denoising step may faci...

Reproducibility of tumor uptake heterogeneity characterization through textural feature analysis in 18F-FDG PET.

Archive ouverte | Tixier, Florent | CCSD

International audience. UNLABELLED: (18)F-FDG PET measurement of standardized uptake value (SUV) is increasingly used for monitoring therapy response and predicting outcome. Alternative parameters computed through t...

Evaluation of a 3D local multiresolution algorithm for the correction of partial volume effects in positron emission tomography.

Archive ouverte | Le Pogam, Adrien | CCSD

International audience. PURPOSE: Partial volume effects (PVEs) are consequences of the limited spatial resolution in emission tomography leading to underestimation of uptake in tissues of size similar to the point s...

Chargement des enrichissements...