Development of French Indoor Air Quality Guidelines. Method and example for Formaldehyde

Archive ouverte

Mandin, Corinne | Bonvallot, Nathalie | Kirchner, Séverine | Alary, René | Cabanes, Pierre-André | Doornaert, Blandine | Dor, Frédéric | Gourier-Fréry, Claire | Le Moullec, Yvon | Mullot, Jean-Ulrich | Peel, Anne-Elisabeth | Rousselle, Christophe

Edité par CCSD -

International audience. Indoor air quality (IAQ) guidelines provide safe levels of indoor pollutant concentrations below which adverse health effects are not expected to occur in general population, including sensitive subgroups. The French Agency for environmental and occupational health safety (AFSSET) and the French Scientific and technical centre for building (CSTB) have been leading a working group in charge of development of IAQ guidelines based on human toxicological criteria. First, a list of substances of concern was established. Then for each pollutant of concern, existing health effect-based IAQ guidelines recommended by international groups or by other countries are collected. Available human toxicological values from US-Environmental Protection Agency, Agency for Toxic Substances and Disease Registry, Office of Environmental Health Hazard Assessment, Health Canada and Dutch Agency for environmental health are listed as well. After a critical analysis of these values, IAQ guidelines are proposed. Elaboration of IAQ guidelines for formaldehyde is presented.

Consulter en ligne

Suggestions

Du même auteur

Development of French Indoor Air quality guidelines

Archive ouverte | Mandin, Corinne | CCSD

International audience. Indoor air quality guidelines (IAQGs) provide safe levels of indoor pollutant concentrations below which adverse health effects are not expected to occur in the general population, including ...

Valeurs guides de qualité d'air intérieur pour le formaldéhyde

Archive ouverte | Bonvallot, Nathalie | CCSD

La qualité de l'air intérieur représente une priorité de santé publique. Les Valeurs Guides de Qualité d'Air Intérieur (VGAI) fournissent une référence sanitaire pour protéger la population exposée dans les environnements intérieu...

Setting of French indoor air quality guidelines for chronic exposure to benzene

Archive ouverte | Keirsbulck, Marion | CCSD

International audience. Indoor air quality guidelines (IAQGs) provide safe levels of indoor pollutant concentrations below which adverse health effects are not expected to occur in the general population, including ...