Field evaluation and impact on clinical management of a rapid diagnostic kit that detects dengue NS1, IgM and IgG.

Archive ouverte

Andries, Anne-Claire | Duong, Veasna | Ngan, Chantha | Ong, Sivuth | Huy, Rekol | Sroin, Kim Kim | Te, Vantha | Y, Bunthin | Try, Patrich Lorn | Buchy, Philippe

Edité par CCSD ; Public Library of Science -

International audience. BACKGROUND: Dengue diagnosis is complex and until recently only specialized laboratories were able to definitively confirm dengue infection. Rapid tests are now available commercially making biological diagnosis possible in the field. The aim of this study was to evaluate a combined dengue rapid test for the detection of NS1 and IgM/IgG antibodies. The evaluation was made prospectively in the field conditions and included the study of the impact of its use as a point-of-care test for case management as well as retrospectively against a panel of well-characterized samples in a reference laboratory. METHODOLOGY/PRINCIPAL FINDINGS: During the prospective study, 157 patients hospitalized for a suspicion of dengue were enrolled. In the hospital laboratories, the overall sensitivity, specificity, PPV and NPV of the NS1/IgM/IgG combination tests were 85.7%, 83.9%, 95.6% and 59.1% respectively, whereas they were 94,4%, 90.0%, 97.5% and 77.1% respectively in the national reference laboratory at Institut Pasteur in Cambodia. These results demonstrate that optimal performances require adequate training and quality assurance. The retrospective study showed that the sensitivity of the combined kit did not vary significantly between the serotypes and was not affected by the immune status or by the interval of time between onset of fever and sample collection. The analysis of the medical records indicates that the physicians did not take into consideration the results obtained with the rapid test including for care management and use of antibiotic therapy. CONCLUSIONS: In the context of our prospective field study, we demonstrated that if the SD Bioline Dengue Duo kit is correctly used, a positive result highly suggests a dengue case but a negative result doesn't rule out a dengue infection. Nevertheless, Cambodian pediatricians in their daily practice relied on their clinical diagnosis and thus the false negative results obtained did not directly impact on the clinical management.

Suggestions

Du même auteur

Dengue diagnosis : three solutions to improve patients’ management and to facilitate epidemiological studies. Diagnostic de la dengue : trois solutions pour améliorer la prise en charge des patients et faciliter les études épidémiologiques

Archive ouverte | Andries, Anne-Claire | CCSD

Dengue is a viral disease transmitted by Aedes species mosquitoes, in tropical and subtropical regions. Dengue virus (DENV) belongs to the family Flaviviridae, genus Flavivirus. Although most DENV infections are asymptomatic or re...

Evaluation of the performances of six commercial kits designed for dengue NS1 and anti-dengue IgM, IgG and IgA detection in urine and saliva clinical specimens

Archive ouverte | Andries, Anne-Claire | CCSD

International audience. Rapid diagnostic tests (RDTs) have been commercialized in order to help physicians in dengue diagnosis. Until recently, only blood samples were used for those tests but it has been shown in s...

Reemergence of Chikungunya Virus in Cambodia

Archive ouverte | Duong, Veasna | CCSD

International audience. Chikungunya virus (CHIKV), probably Asian genotype, was first detected in Cambodia in 1961. Despite no evidence of acute or recent CHIKV infections since 2000, real-time reverse transcription...