Asymmetric pulses delivered by a cochlear implant allow a reduction in evoked firing rate and in spatial activation in the guinea pig auditory cortex

Archive ouverte

Adenis, Victor | Partouche, Elie | Stahl, P | Gnansia, D | Huetz, Chloé | Edeline, Jean-Marc

Edité par CCSD ; Elsevier -

International audience. Despite that fact that the cochlear implant (CI) is one of the most successful neuro-prosthetic devices which allows hearing restoration, several aspects still need to be improved. Interactions between stimulating electrodes through current spread occurring within the cochlea drastically limit the number of discriminable frequency channels and thus can ultimately result in poor speech perception. One potential solution relies on the use of new pulse shapes, such as asymmetric pulses, which can potentially reduce the current spread within the cochlea. The present study characterized the impact of changing electrical pulse shapes from the standard biphasic symmetric to the asymmetrical shape by quantifying the evoked firing rate and the spatial activation in the guinea pig primary auditory cortex (A1). At a fixed charge, the firing rate and the spatial activation in A1 decreased by 15 to 25 % when asymmetric pulses were used to activate the auditory nerve fibers, suggesting a potential reduction of the spread of excitation inside the cochlea. A strong “polarity-order” effect was found as the reduction was more pronounced when the first phase of the pulse was cathodic with high amplitude. These results suggest that the use of asymmetrical pulse shapes in clinical settings can potentially reduce the channel interactions in CI users.

Suggestions

Du même auteur

What Is the Benefit of Ramped Pulse Shapes for Activating Auditory Cortex Neurons? An Electrophysiological Study in an Animal Model of Cochlear Implant

Archive ouverte | Partouche, Elie | CCSD

International audience. In all commercial cochlear implant (CI) devices, the activation of auditory nerve fibers is performed with rectangular pulses that have two phases of opposite polarity. Recently, several pape...

Increased Threshold and Reduced Firing Rate of Auditory Cortex Neurons after Cochlear Implant Insertion

Archive ouverte | Partouche, Elie | CCSD

International audience. The cochlear implant (CI) is the most successful neuroprosthesis allowing thousands of patients with profound hearing loss to recover speech understanding. Recently, cochlear implants have be...

A Single Exposure to GSM-1800 MHz Signals in the Course of an Acute Neuroinflammatory Reaction can Alter Neuronal Responses and Microglial Morphology in the Rat Primary Auditory Cortex

Archive ouverte | Occelli, Florian | CCSD

International audience. During mobile phone conversations, the temporal lobe neural networks involved in processing auditory information are exposed to electromagnetic fields (EMF) such as pulse-modulated GSM-1800 M...

Chargement des enrichissements...