3D printed PLGA implants: How the filling density affects drug release. 3D printed PLGA implants: How the filling density affects drug release.

Archive ouverte

Bassand, C. | Siepmann, F. | Benabed, L. | Verin, J. | Freitag, J. | Charlon, Sébastien | Soulestin, J. | Siepmann, J.

Edité par CCSD ; Elsevier -

International audience. Different types of ibuprofen-loaded, poly (D,L lactic-co-glycolic acid) (PLGA)-based implants were prepared by 3D printing (Droplet Deposition Modeling). The theoretical filling density of the mesh-shaped implants was varied from 10 to 100%. Drug release was measured in agarose gels and in well agitated phosphate buffer pH 7.4. The key properties of the implants (and dynamic changes thereof upon exposure to the release media) were monitored using gravimetric measurements, optical microscopy, Differential Scanning Calorimetry, Gel Permeation Chromatography, and Scanning Electron Microscopy. Interestingly, drug release was similar for implants with 10 and 30% filling density, irrespective of the experimental set-up. In contrast, implants with 100% filling density showed slower release kinetics, and the shape of the release curve was altered in agarose gels. These observations could be explained by the existence (or absence) of a continuous aqueous phase between the polymeric filaments and the “orchestrating role” of substantial system swelling for the control of drug release. At lower filling densities, it is sufficient for the drug to be released from a single filament. In contrast, at high filling densities, the ensemble of filaments acts as a much larger (more or less homogeneous) polymeric matrix, and the average diffusion pathway to be overcome by the drug is much longer. Agarose gel (mimicking living tissue) hinders substantial PLGA swelling and delays the onset of the final rapid drug release phase. This improved mechanistic understanding of the control of drug release from PLGA-based 3D printed implants can help to facilitate the optimization of this type of advanced drug delivery systems.

Suggestions

Du même auteur

3D printed PLGA implants: APF DDM vs. FDM

Archive ouverte | Bassand, C. | CCSD

International audience. 3D Printing offers a considerable potential for personalized medicines. This is especially true for customized biodegradable implants, matching the specific needs of each patient. Poly(lactic...

Hot melt extruded PLGA implants loaded with ibuprofen: How heat exposure alters the physical drug state

Archive ouverte | Bassand, C. | CCSD

International audience. Hot melt extrusion offers an interesting potential for the manufacturing of poly(lactic-co-glycolic acid) (PLGA)-based implants. However, the heat treatment might substantially alter the poly...

Mechanistic explanation of the (up to) 3 release phases of PLGA microparticles: Diprophylline dispersions

Archive ouverte | Tamani, F. | CCSD

International audience

Chargement des enrichissements...