Inter‐center reproducibility of standard and advanced echocardiographic parameters in the EACVI‐AFib echo registry

Archive ouverte

Santoro, Ciro | Donal, Erwan | Magne, Julien | Sade, Leyla Elif | Penicka, Martin | Katbeh, Asim | Cosyns, Bernard | Cameli, Matteo | Hanzevacki, Jadranka Separovic | Luksic, Vlatka Reskovic | Agricola, Eustachio | Citro, Rodolfo | Hagendorff, Andreas | Lancellotti, Patrizio | Habib, Gilbert | Moreo, Antonella | Cardim, Nuno | Parato, Vito Maurizio | Neskovic, Alexsandar | Rosca, Monica | Galli, Elena | Motoc, Andreea | Mandoli, Giulia | Ingallina, Giacomo | Prota, Costantina | Stoebe, Stephen | Piette, Caroline | Mouhat, Basile | Carbone, Andreina | Chiara, Benedetta De | Ilardi, Federica | Stankovic, Ivan | Zamorano, Jose Luis | Popescu, Bogdan Alexandru | Edvardsen, Thor | Galderisi, Maurizio

Edité par CCSD ; Wiley -

International audience. Aim: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe.Methods: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS).Results: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively.Conclusion: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.

Consulter en ligne

Suggestions

Du même auteur

Echocardiographic reference ranges for normal left ventricular layer-specific strain: results from the EACVI NORRE study

Archive ouverte | Tsugu, Toshimitsu | CCSD

International audience. Aims  - To obtain the normal range for 2D echocardiographic (2DE) measurements of left ventricular (LV) layer-specific strain from a large group of healthy volunteers of both genders over a w...

Correlation between non-invasive myocardial work indices and main parameters of systolic and diastolic function: results from the EACVI NORRE study

Archive ouverte | Manganaro, Roberta | CCSD

International audience. The present study sought to evaluate the correlation between indices of non-invasive myocardial work (MW) and left ventricle (LV) size, traditional and advanced parameters of LV systolic and ...

Echocardiographic reference ranges for normal non-invasive myocardial work indices results from the EACVI NORRE study

Archive ouverte | Manganaro, Roberta | CCSD

International audience. Aims - To obtain the normal ranges for 2D echocardiographic (2DE) indices of myocardial work (MW) from a large group of healthy volunteers over a wide range of ages and gender. Methods and r...

Chargement des enrichissements...