Semi-automatic detection of myocardial trabeculation using cardiovascular magnetic resonance: correlation with histology and reproducibility in a mouse model of non-compaction

Archive ouverte

Frandon, Julien | Bricq, Stéphanie | Bentatou, Zakarya | Marcadet, Laetitia | Barral, Pierre, Antoine | Finas, Mathieu | Fagret, Daniel | Kober, Frank | Habib, Gilbert | Bernard, Monique | Lalande, Alain | Miquerol, Lucile | Jacquier, Alexis

Edité par CCSD ; BioMed Central -

International audience. Background: The definition of left ventricular (LV) non-compaction is controversial, and discriminating between normal and excessive LV trabeculation remains challenging. Our goal was to quantify LV trabeculation on cardiovascular magnetic resonance (CMR) images in a genetic mouse model of non-compaction using a dedicated semi-automatic software package and to compare our results to the histology used as a gold standard.MethodsAdult mice with ventricular non-compaction were generated by conditional trabecular deletion of Nkx2–5. Thirteen mice (5 controls, 8 Nkx2–5 mutants) were included in the study. Cine CMR series were acquired in the mid LV short axis plane (resolution 0.086 × 0.086x1mm3) (11.75 T). In a sub set of 6 mice, 5 to 7 cine CMR were acquired in LV short axis to cover the whole LV with a lower resolution (0.172 × 0.172x1mm3). We used semi-automatic software to quantify the compacted mass (Mc), the trabeculated mass (Mt) and the percentage of trabeculation (Mt/Mc) on all cine acquisitions. After CMR all hearts were sliced along the short axis and stained with eosin, and histological LV contouring was performed manually, blinded from the CMR results, and Mt, Mc and Mt/Mc were quantified. Intra and interobserver reproducibility was evaluated by computing the intra class correlation coefficient (ICC).Results: Whole heart acquisition showed no statistical significant difference between trabeculation measured at the basal, midventricular and apical parts of the LV. On the mid-LV cine CMR slice, the median Mt was 0.92 mg (range 0.07–2.56 mg), Mc was 12.24 mg (9.58–17.51 mg), Mt/Mc was 6.74% (0.66–17.33%). There was a strong correlation between CMR and the histology for Mt, Mc and Mt/ Mc with respectively: r2 = 0.94 (p < 0.001), r2 = 0.91 (p < 0.001), r2 = 0.83 (p < 0.001). Intra- and interobserver reproducibility was 0.97 and 0.8 for Mt; 0.98 and 0.97 for Mc; 0.96 and 0.72 for Mt/Mc, respectively and significantly more trabeculation was observed in the Mc Mutant mice than the controls.Conclusion: The proposed semi-automatic quantification software is accurate in comparison to the histology and reproducible in evaluating Mc, Mt and Mt/ Mc on cine CMR.

Suggestions

Du même auteur

Semiautomatic detection of myocardial contours in order to investigate normal values of the left ventricular trabeculated mass using MRI

Archive ouverte | Bricq, Stéphanie | CCSD

International audience. PurposeTo propose, assess, and validate a semiautomatic method allowing rapid and reproducible measurement of trabeculated and compacted left ventricular (LV) masses from cardiac magnetic res...

Exercise stress CMR reveals reduced aortic distensibility and impaired right-ventricular adaptation to exercise in patients with repaired tetralogy of Fallot

Archive ouverte | Habert, Paul | CCSD

International audience. The aim of our study was to evaluate the feasibility of exercise cardiac magnetic resonance (CMR) in patients with repaired tetralogy of Fallot (RTOF) and to assess right and left ventricular...

Prognostic value of cardiovascular magnetic resonance T1 mapping and extracellular volume fraction in nonischemic dilated cardiomyopathy

Archive ouverte | Cadour, Farah | CCSD

International audience. Abstract Background Heart failure- (HF) and arrhythmia-related complications are the main causes of morbidity and mortality in patients with nonischemic dilated cardiomyopathy (NIDCM). Cardio...

Chargement des enrichissements...