Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves

Archive ouverte

Roux, Emmanuel | Varray, François | Petrusca, Lorena | Cachard, Christian | Tortoli, Piero | Liebgott, Hervé

Edité par CCSD ; Nature Publishing Group -

International audience. Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the need of controlling very large numbers of probe elements. Although this problem may be overcome by the use of 2-D sparse arrays, just a few experimental results have so far corroborated the validity of this approach. In this paper, we experimentally compare the performance of a fully wired 1024-element (32 × 32) array, assumed as reference, to that of a 256-element random and of an " optimized " 2-D sparse array, in both focused and compounded diverging wave (DW) transmission modes. The experimental results in 3-D focused mode show that the resolution and contrast produced by the optimized sparse array are close to those of the full array while using 25% of elements. Furthermore, the experimental results in 3-D DW mode and 3-D focused mode are also compared for the first time and they show that both the contrast and the resolution performance are higher when using the 3-D DW at volume rates up to 90/second which represent a 36x speed up factor compared to the focused mode.

Suggestions

Du même auteur

3D Diverging Waves with 2D Sparse Arrays: A Feasibility Study

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Background, Motivation and ObjectiveVery high frame rates can be reached both in 2D and 3D ultrasound imaging thanks to diverging waves (DWs) transmission. Up to now 3D ultrafast imaging has ...

Comparison of different optimized irregular sparse 2D ultrasound arrays

Archive ouverte | Diarra, Bakary | CCSD

International audience. The role of 2D matrix arrays in the realization of real time 3D ultrasound imaging is crucial as the latter permit to acquire a complete volume. The lack of control systems for these arrays c...

2-D Ultrasound Sparse Arrays Multidepth Radiation Optimization Using Simulated Annealing and Spiral-Array Inspired Energy Functions

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Full matrix arrays are excellent tools for 3-D ultrasound imaging, but the required number of active elements is too high to be individually controlled by an equal number of scanner channels....

Chargement des enrichissements...