MR-Guided Thermotherapy of Abdominal Organs Using a Robust PCA-Based Motion Descriptor

Archive ouverte

Denis de Senneville, Baudouin | Ries, Mario | Maclair, Grégory | Moonen, Chrit

Edité par CCSD ; Institute of Electrical and Electronics Engineers -

International audience. Thermotherapies can now be guided in real-time using magnetic resonance imaging (MRI). This technique is rapidly gaining importance in interventional therapies for abdominal organs such as liver and kidney. An accurate on-line estimation and characterization of organ displacement is mandatory to prevent misregistration and correct for motion related thermometry artifacts. In addition, when the ablation is performed with an extracorporal heating device such as High Intensity Focused Ultrasound (HIFU), the continuous estimation of the organ displacement is the basis for the dynamic adjustment of the focal point position to track the targeted pathological tissue. In this paper, we describe the use of an optimized PCA-based motion descriptor to characterize in real-time the complex organ deformation during the therapy. The PCA was used to detect, in a preparative learning step, spatio-temporal coherences in the motion of the targeted organ. During hyperthermia, incoherent motion patterns could be discarded, which enabled improvements in motion estimation robustness, the compensation of motion related errors in thermal maps, and the adjustment of the beam position. The suggested method was evaluated for a moving phantom , and tested in-vivo in the kidney and the liver of twelve healthy volunteers under free breathing conditions. The ability to perform a MR-guided thermotherapy in-vivo during HIFU intervention was finally demonstrated on a porcine kidney.

Suggestions

Du même auteur

Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound

Archive ouverte | Denis de Senneville, Baudouin | CCSD

International audience. Focused ultrasound is a unique and non-invasive technique for the local deposition of thermal energy deep inside the body. MRI guidance offers the additional benefits of excellent target visu...

An Adaptive Non-Local-Means Filter for Real-Time MR-Thermometry

Archive ouverte | Zachiu, Cornel | CCSD

International audience. Proton resonance frequency shift-based magnetic resonance thermometry is a currently used technique for monitoring temperature during targeted thermal therapies. However, in order to provide ...

Motion correction in MR thermometry of abdominal organs: A comparison of the referenceless vs. the multibaseline approach

Archive ouverte | Denis de Senneville, Baudouin | CCSD

International audience. Reliable temperature and thermal-dose measurements using proton resonance frequency shift-based MR-thermometry AQ2 for MR-guided ablation of abdominal organs require a robust correction of ar...

Chargement des enrichissements...