Comparison of different optimized irregular sparse 2D ultrasound arrays

Archive ouverte

Diarra, Bakary | Roux, Emmanuel | Liebgott, Hervé | Ravi, Samikannu | Robini, Marc C. | Tortoli, Piero | Cachard, Christian

Edité par CCSD -

International audience. The role of 2D matrix arrays in the realization of real time 3D ultrasound imaging is crucial as the latter permit to acquire a complete volume. The lack of control systems for these arrays containing thousands of elements and the dimension of connection cables for such a number of elements are the main obstacles to the use of these technologies. The sparse array techniques present a solid candidate to solve these technological limitations but give rise to beam pattern deteriorations in terms of energy loss and unwanted lobes apparition. The irregular positioning of the array elements permits to drastically decrease the unwanted lobes while the energy loss may be compensated by increasing the element size. However, as elements get larger, the directivity decreases. To solve this directivity reduction, we propose to combine elements of different sizes in such a manner that a broad directivity is maintained using small elements whereas the energy loss may be compensated by wide ones. Additionally, an innovative simulated annealing based algorithm is used to refine the array beam profile when the active element number is set to 256. The results compared to those obtained by the basic non-grid array show significant improvement in the beam pattern.

Consulter en ligne

Suggestions

Du même auteur

2-D Ultrasound Sparse Arrays Multidepth Radiation Optimization Using Simulated Annealing and Spiral-Array Inspired Energy Functions

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Full matrix arrays are excellent tools for 3-D ultrasound imaging, but the required number of active elements is too high to be individually controlled by an equal number of scanner channels....

Wideband 2-D Array Design Optimization With Fabrication Constraints for 3-D US Imaging

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Ultrasound (US) 2-D arrays are of increasing interest due to their electronic steering capability to investigate 3-D regions without requiring any probe movement. These arrays are typically p...

Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves

Archive ouverte | Roux, Emmanuel | CCSD

International audience. Three dimensional ultrasound (3-D US) imaging methods based on 2-D array probes are increasingly investigated. However, the experimental test of new 3-D US approaches is contrasted by the nee...

Chargement des enrichissements...