Blind Source Separation Methods Applied to Muscle Artefacts Removing from Epileptic Eeg Recording: A Comparative Study.

Archive ouverte

Kachenoura, Amar | Safieddine, Doha | Albera, Laurent | Birot, Gwénaël | Wendling, Fabrice | Senhadji, Lotfi | Merlet, Isabelle

Edité par CCSD -

International audience. Electroencephalogram (EEG) recordings are often contaminated with muscle artifacts. These artifacts obscure the EEG and complicate its interpretation or even make the interpretation unfeasible. In this paper, realistic spike EEG signals are simulated from the activation of a 5 cm2 epileptic patch in the left superior temporal gyrus. Background activities and real muscle artifacts are then added to the simulated data. We compare the efficiency of Empirical Mode Decomposition (EMD), Independent Component Analysis (ICA) and Blind Source Separation based on Canonical Correlation Analysis (BSS-CCA) to remove muscle artifacts from the EEG signals. The quantitative comparison indicates that the EMD approach exhibits a better performance than ICA and BSS-CCA, especially in the case of very low Signal to Noise Ratio (SNR).

Suggestions

Du même auteur

ICA versus CCA pour le débruitage de signaux épileptiques intercritiques : une étude comparative de performances basée sur la localisation de la zone épileptogène. [ICA vs CCA for the denoising of interictal epileptic signals: A study of performance based on source localization.]

Archive ouverte | Safieddine, Doha | CCSD

International audience. We propose in this study to compare the performances of two stochastic approaches (independent component analysis [ICA] and canonical correlation analysis [CCA]) to remove the muscular artefa...

Performances des approches déterministes et stochastiques pour le débruitage des signaux épileptiques intercritiques

Archive ouverte | Safieddine, Doha | CCSD

National audience. On propose dans cette étude de comparer les performances d'une approche déterministe (Décomposition Modale Empirique, EMD), et deux approches stochastiques (l'Analyse en Composantes Indépendantes,...

Removal of muscle artifact from EEG data: comparison between stochastic (ICA and CCA) and deterministic (EMD and wavelet-based) approaches

Archive ouverte | Safieddine, Doha | CCSD

International audience. Electroencephalographic (EEG) recordings are often contaminated with muscle artifacts. This disturbing myogenic activity not only strongly affects the visual analysis of EEG, but also most su...

Chargement des enrichissements...