Endocardial acceleration (sonR) vs. ultrasound-derived time intervals in recipients of cardiac resynchronization therapy systems.

Archive ouverte

Donal, Erwan | Giorgis, Lionel | Cazeau, Serge | Leclercq, Christophe | Senhadji, Lotfi | Amblard, Amel | Jauvert, Gael | Burban, Marc | Hernández, Alfredo | Mabo, Philippe

Edité par CCSD ; Oxford University Press (OUP) -

International audience. AIMS: Optimization of cardiac resynchronization therapy (CRT) requires the gathering of cardiac functional information. An accurate timing of the phases of the cardiac cycle is key in the optimization process. METHODS AND RESULTS: We compared Doppler echocardiography to an automated system, based on the recording of sonR (formerly endocardial acceleration), in the detection of mitral and aortic valves closures and measurements of the duration of systole and diastole. We prospectively studied, under various conditions of cardiac stimulation, 75 recipients of CRT systems (69% men), whose mean age was 72 ± 9.2 years, left ventricular ejection fraction 35 ± 11%, baseline QRS duration 154 ± 29 ms, and New York Heart Association functional class 3.0 ± 0.7. We simultaneously recorded (i) sonR, detected by a non-invasive piezoelectric micro-accelerometer sensor clipped onto an electrode located in the parasternal region, (b) electrocardiogram, and (c) Doppler audio signals, using a multichannel data acquisition and analysis system. The correlation between timing of mitral and aortic valve closure by sonR vs. Doppler signals was examined by linear regression analysis. Correlation coefficients and the average absolute error were calculated. A concordance in the timing of the mitral (r = 0.86, error = 9.7 ms) and aortic (r = 0.93, error = 9.7 ms) valves closure was observed between the two methods in 94% of patients. Similarly, sonR and the Doppler-derived measurements of systolic (r = 0.85, error = 13.4 ms) and diastolic (r = 0.99, error = 12 ms) interval durations were concordant in 80% of patients. CONCLUSION: A high concordance was found between sonR and the cardiac ultrasound in the timings of aortic and mitral valve closures and in the estimation of systolic and diastolic intervals durations. These observations suggest that sonR could be used to monitor cardiac function and adaptively optimize CRT systems.

Consulter en ligne

Suggestions

Du même auteur

Analysis of Cardiac Micro-Acceleration Signals for the Estimation of Systolic and Diastolic Time Intervals in Cardiac Resynchronization Therapy

Archive ouverte | Giorgis, Lionel | CCSD

International audience. Heart sounds, measured via cardiac micro-acceleration (CMA), carry valuable information about the mechanical and hemodynamic function of the heart. The aim of the present study is to estimate...

Optimal algorithm switching for the estimation of systole period from cardiac microacceleration signals (SonR).

Archive ouverte | Giorgis, Lionel | CCSD

International audience. Previous studies have shown that cardiac microacceleration signals, recorded either cutaneously, or embedded into the tip of an endocardial pacing lead, provide meaningful information to char...

Kinesthetic stimulation for obstructive sleep apnea syndrome: An “on-off” proof of concept trial

Archive ouverte | Hernandez, Alfredo | CCSD

International audience. Obstructive sleep apnea (OSA) occurs when the upper airway narrows or collapses due to the loss of upper airway muscle activation at sleep onset. This study investigated the effectiveness of ...

Chargement des enrichissements...