Reduction of β-radiation exposure during preparation of 188Re-labelled Lipiodol for hepatocellular carcinoma treatment.

Archive ouverte

Lepareur, Nicolas | Laffont, Sophie | Ardisson, Valérie | Noiret, Nicolas | Garin, Etienne

Edité par CCSD ; Lippincott, Williams & Wilkins -

International audience. Rhenium-188 (188Re) is of widespread interest for treating various diseases because of its attractive physical and chemical properties. The routine preparation of therapeutic doses of 188Re-labelled tracers can result in significant radiation exposure to the operator. We studied the impact of automating the preparation of 188Re-Lipiodol on the radiochemist's exposure, as well as the importance of the model of syringe shielding. To monitor radiation exposure continuously readable electronic personal dosimeters were used. Thermoluminescence dosimeters were fixed to the probable most exposed fingers of the radiochemist during preparation of the radiotracer and during the syringing. Dose rates were measured using a Babyline. Automation of the synthesis reduced personal dose equivalents from 2.60±4.35 to 1.61±1.20 µSv/GBq [Hp(10)] and from 38.37±55.28 to 21.84±16.14 µSv/GBq [Hp(0.07)]. Dose to the extremities was also reduced (-80% for the right hand; -58% for the left one). The Lemer-Pax PSWG syringe shield led to a slightly lower dose to the hands compared with the Medisystem (1.1±0.27 vs. 1.34±0.6 mSv/GBq for the right finger). Automation of the synthesis leads to a significant decrease in radiation exposure to the operator. The Lemer-Pax PSWG syringe shield provides better hand protection than the smaller Medisystem Mediclic.

Consulter en ligne

Suggestions

Du même auteur

Preliminary results of the Phase 1 Lip-Re I clinical trial: biodistribution and dosimetry assessments in hepatocellular carcinoma patients treated with 188Re-SSS Lipiodol radioembolization

Archive ouverte | Delaunay, Kostas | CCSD

International audience. Purpose: This study sought to provide preliminary results on the biodistribution and dosimetry following intra-arterial liver injection of 188Re-SSS Lipiodol on hepatocellular carcinoma patie...

Optimization of hepatocarcinoma uptake with radiolabeled lipiodol: development of new lipiodol formulations with increased viscosity.

Archive ouverte | Becker, Stéphanie | CCSD

International audience. The aim of this study was to develop new Lipiodol formulations with increased viscosities to augment Lipiodol embolic effect and optimize efficiency of radiolabeled Lipiodol in hepatocarcinom...

Increased Lipiodol uptake in hepatocellular carcinoma possibly due to increased membrane fluidity by dexamethasone and tamoxifen.

Archive ouverte | Becker, Stéphanie | CCSD

International audience. INTRODUCTION: Lipiodol is used as a vector for chemoembolization or internal radiotherapy in unresectable hepatocellular carcinomas (HCCs). The aim of this study is to improve the tumoral upt...

Chargement des enrichissements...